Welcome to the Covidien Kendall SCD 700 Series User Manual, your comprehensive guide to understanding and operating the sequential compression system designed to prevent DVT and enhance circulation.
1.1 Overview of the SCD 700 Series
The Covidien Kendall SCD 700 Series is a state-of-the-art sequential compression device designed to prevent deep vein thrombosis (DVT) and enhance patient circulation. This system incorporates Covidien’s patented Vascular Refill Detection Technology, which customizes therapy based on individual patient physiology. The device features a user-friendly interface with animated icons, ensuring intuitive operation. It is intended for both clinical and home use, offering a reliable solution for circulation enhancement and VTE prophylaxis. The SCD 700 Series is compact, lightweight, and designed for ease of use, making it a versatile tool in healthcare settings. Its advanced technology and clinically proven performance make it a trusted choice for patient care.
1.2 Key Features and Benefits
The Covidien Kendall SCD 700 Series offers several key features that enhance its functionality and patient care. Its patented Vascular Refill Detection Technology ensures personalized therapy by adapting to each patient’s physiological needs. The device also features a user-friendly graphical interface with animated icons, making operation intuitive and straightforward. Additionally, the system includes three error types—User Resettable, Manual Reset Required, and Service Required—allowing for quick troubleshooting and minimizing downtime. The lightweight and compact design ensures portability, while the snug-fit sleeves provide comfortable and effective compression. These features collectively contribute to improved circulation, DVT prevention, and enhanced patient comfort, making the SCD 700 Series a versatile and reliable choice for both clinical and home settings.
Product Overview
The Covidien Kendall SCD 700 Series is a state-of-the-art sequential compression system designed to prevent deep vein thrombosis (DVT) and improve patient circulation.
2.1 Design and Functionality
The Covidien Kendall SCD 700 Series features a sleek, user-friendly design with a graphical user interface and animated icons for intuitive operation. Its advanced functionality includes Vascular Refill Detection Technology, which customizes therapy based on individual patient physiology. The system is designed as an all-in-one solution for preventing venous thromboembolism (VTE) and enhancing circulation. The controller is compact and lightweight, making it easy to use in various clinical settings. It includes multiple compression sleeves and cuffs that fit snugly, ensuring effective and comfortable therapy. The device also incorporates error detection with three types of alerts: User Resettable, Manual Reset Required, and Service Required. This ensures prompt troubleshooting and maintenance, maintaining optimal performance and patient safety. The design emphasizes ease of use and durability, making it a reliable choice for healthcare professionals.
2.2 Patented Vascular Refill Detection Technology
The Covidien Kendall SCD 700 Series employs patented Vascular Refill Detection Technology, a groundbreaking innovation that personalizes therapy by monitoring and adapting to each patient’s physiological needs. This advanced system dynamically adjusts compression cycles to optimize blood flow and promote venous return. By detecting the refill rate of blood in the veins, it ensures that compression is delivered at the most effective intervals. This technology minimizes the risk of deep vein thrombosis (DVT) while enhancing patient comfort. The adaptive nature of this feature allows for tailored treatment, making it highly effective across diverse patient populations. This proprietary technology underscores the device’s commitment to clinical excellence and patient-centric care, setting it apart as a leader in sequential compression systems.
Safety Precautions
Ensure safe operation by inspecting power cords for damage and avoiding use in hazardous environments. Adhere to all warnings to prevent device malfunction and patient harm.
3.1 General Safety Warnings
The Covidien Kendall SCD 700 Series requires adherence to specific safety guidelines to ensure proper function and patient safety. Do not open or modify the device, as it contains no user-serviceable parts. Always inspect the power cord for damage or fraying before use. The device should only be used in environments suitable for medical equipment and must be kept away from hazardous materials. Ensure the system is used solely for its intended purpose: enhancing circulation and preventing deep vein thrombosis (DVT). Never apply the device to patients with active bleeding, severe vascular disease, or other contraindications listed in the manual. Proper usage and adherence to these warnings are critical to preventing complications and ensuring effective therapy.
3.2 Device-Specific Safety Considerations
Adhere to device-specific safety measures for the Covidien Kendall SCD 700 Series. The controller contains no user-serviceable parts; any tampering or unauthorized repairs void the warranty. Regularly inspect the power cord for fraying or damage, and avoid using the device if such issues are found. Do not expose the system to extreme temperatures or moisture, as this may impair functionality. Cleaning should only be performed with a soft cloth and non-aggressive cleaning agents to prevent damage. Additionally, be aware of the device’s error types: User Resettable, Manual Reset Required, and Service Required. Addressing these promptly ensures safe and effective operation. Always follow Covidien’s guidelines for maintenance and troubleshooting to uphold patient and user safety.
Installation and Setup
Begin by unboxing and inspecting the Covidien Kendall SCD 700 Series for any visible damage. Carefully remove the controller from its packaging and ensure all components are included. Connect the sleeves and tubing to the device, following the provided diagrams. Secure the system on a stable surface, ensuring proper ventilation. Before powering on, verify that all connections are tight and the device is placed in a dry, cool environment. Refer to the manual for specific setup instructions to ensure optimal functionality and safety during operation. Always follow Covidien’s guidelines for installation to prevent malfunctions and ensure patient safety. Proper setup is crucial for effective therapy delivery.
4.1 Unboxing and Initial Inspection
When unpacking the Covidien Kendall SCD 700 Series, carefully remove the controller and components from the packaging. Inspect the device for any visible damage or wear. Verify that all essential parts, such as the controller, sleeves, tubing, and power cord, are included; Ensure the system is free from debris or moisture, which could interfere with its operation. Check the power cord for fraying or damage; if damaged, contact Covidien’s service center immediately. Before proceeding, wipe the device with a soft, dry cloth to ensure cleanliness. Familiarize yourself with the components and their connections to prepare for proper assembly and setup. Proper inspection ensures the device is ready for safe and effective use. Always follow the manufacturer’s guidelines for handling and preparing the system.
4.2 Connecting Components and Sleeves
To ensure proper functionality, carefully connect the components and sleeves of the Covidien Kendall SCD 700 Series. Begin by attaching the tubing to the controller and sleeves, ensuring a secure fit. Align the connectors properly to avoid leaks or disconnections during operation. Next, wrap the sleeves around the patient’s legs, making sure they fit snugly but not too tightly—allow enough space for two fingers to fit comfortably between the sleeve and the leg. Secure the sleeves with the provided fasteners, ensuring they are evenly tightened. Double-check all connections for stability and inspect for any signs of damage or wear. Properly connected components are essential for effective therapy and patient safety. Always refer to the manual for specific guidance on connecting and securing the sleeves and tubing.
Operating Instructions
Power on the device, navigate the graphical interface, and select the desired therapy mode. Adjust compression settings as prescribed, monitor operation, and ensure patient comfort throughout therapy.
5.1 Starting the Device
To start the Covidien Kendall SCD 700 Series, ensure all components are properly connected. Power on the device using the main switch. The system will perform a self-test, indicated by the graphical user interface lighting up. Once the self-test is complete, select the desired therapy mode using the intuitive interface with animated icons. Verify that the tubing is securely connected to both the device and the sleeves. Ensure the sleeves are properly fitted to the patient’s legs, allowing enough room for two fingers to fit comfortably. Press the “Start” button to initiate therapy. The device will begin delivering sequential compression based on the selected settings. Always refer to the user manual for specific startup procedures and safety guidelines.
5.2 Adjusting Compression Settings
Adjusting compression settings on the Covidien Kendall SCD 700 Series is straightforward via the graphical user interface. Use the control panel to select the desired pressure level, typically between 20-40 mmHg. The device features pre-set modes, but settings can be customized to meet individual patient needs. Utilize the arrows or touchscreen (if equipped) to increase or decrease pressure. Ensure the patient is comfortable and monitor the device’s response. The system incorporates patented Vascular Refill Detection Technology to automatically adjust settings based on the patient’s physiology. Always verify proper sleeve fit and connection before making adjustments. Refer to the user manual for detailed instructions on customizing therapy settings and optimizing compression for effective circulation enhancement.
Maintenance and Cleaning
Clean the Kendall SCD 700 Series with a soft cloth and water or non-aggressive detergent. Regularly inspect for damage and ensure proper drying to maintain functionality and hygiene.
6.1 Cleaning the Device
To maintain the Covidien Kendall SCD 700 Series, clean it regularly using a soft, lint-free cloth dampened with water or a non-aggressive detergent. Avoid harsh chemicals or abrasive materials that may damage the surface. Ensure the device is turned off and unplugged before cleaning. Gently wipe down the controller, sleeves, and tubing, focusing on areas with visible dirt or stains. Avoid immersing any part of the device in water or exposing it to excessive moisture, as this could compromise its electrical components. After cleaning, use a dry cloth to thoroughly remove any remaining moisture. Regular cleaning helps prevent contamination and ensures optimal performance. Always refer to the manual for specific cleaning solutions or methods recommended by Covidien.
6.2 Inspecting for Damage
Regularly inspect the Covidien Kendall SCD 700 Series for signs of damage to ensure safe and effective operation. Check the power cord for fraying or cuts; if damaged, send the controller to Covidien’s service center for repair. Inspect tubing and connections for blockages or kinks, which could disrupt therapy. Examine the sleeves for cracks, holes, or excessive wear. Ensure the device’s exterior is free from dirt or corrosion. If any damage is found, discontinue use until repairs are made. Proper inspection helps maintain device performance and patient safety. Refer to the manual for detailed guidance on identifying and addressing potential issues. Regular checks are essential for prolonging the lifespan of the device and ensuring optimal functionality.
Troubleshooting
The Covidien Kendall SCD 700 Series may display errors requiring attention. Common issues include User Resettable, Manual Reset Required, and Service Required errors. Always check connections, power, and settings. Refer to the manual for specific solutions to ensure proper functionality and patient safety.
7.1 Common Error Types
The Covidien Kendall SCD 700 Series may encounter specific error types during operation. These include User Resettable, Manual Reset Required, and Service Required errors. User Resettable errors can often be resolved by the user, such as restarting the device or checking connections. Manual Reset Required errors may involve resetting the system manually or verifying power supply. Service Required errors indicate more serious issues, such as internal malfunctions, requiring professional servicing. Each error type is typically indicated by alarms, lights, or on-screen messages. Refer to the manual for specific troubleshooting steps and solutions to address these errors effectively and ensure uninterrupted therapy. Regular maintenance can help prevent many common issues. Always follow safety guidelines when resolving errors to maintain patient safety and device functionality.
7.2 Resetting and Servicing the Device
Resetting and servicing the Covidien Kendall SCD 700 Series ensures optimal performance and addresses errors. For User Resettable errors, simply power off the device, wait 30 seconds, and restart. If a Manual Reset is needed, locate the reset button (typically on the rear or side panel) and press it firmly for 5-10 seconds. For Service Required errors, contact Covidien’s service center or an authorized technician. Regular servicing includes inspecting the power cord for damage and ensuring all connections are secure. Cleaning the device with a soft cloth and mild detergent is recommended. Always refer to the manual for detailed reset procedures and servicing guidelines to maintain warranty validity and ensure patient safety. Never attempt repairs without proper training to avoid further damage or safety risks.
The Covidien Kendall SCD 700 Series User Manual provides essential guidance for safe and effective use, ensuring optimal patient care and device performance through proper operation, maintenance, and troubleshooting.
8.1 Summary of Key Points
The Covidien Kendall SCD 700 Series is a sequential compression system designed to enhance circulation and prevent deep vein thrombosis (DVT). It features patented Vascular Refill Detection Technology for personalized therapy. Users must adhere to safety precautions, including proper setup and operation. Regular maintenance, such as cleaning and inspecting components, is essential for optimal performance. Troubleshooting common errors and servicing the device as outlined ensure longevity. Always refer to the user manual for detailed instructions and guidelines. Proper use and care of the SCD 700 Series are critical for patient safety and effective therapy outcomes. For further assistance, consult the operation and service manual or contact Covidien support.
8.2 References for Further Information
For additional details, refer to the Operation and Service Manual of the Covidien Kendall SCD 700 Series, available as a downloadable PDF. This manual provides in-depth guidance on setup, troubleshooting, and maintenance. The Product Overview section offers insights into the system’s design and clinical benefits. Page 16 of the manual includes specific instructions for charging and safety precautions. Users can also contact Covidien Sales for further inquiries or technical support. The system’s patented Vascular Refill Detection Technology is detailed in the product specifications. For troubleshooting, review the error types section in the manual, which outlines user-resettable and service-required issues. Always consult these resources to ensure proper use and maintenance of the device.